The GW pipe non-blocking sewage pump adopts an impeller structure and a new type of mechanical seal, which can well transport solid materials and long fibers. Compared with the traditional impeller, the impeller of this pump adopts the form of single flow channel or double flow channel. It is similar to an elbow with the same cross-section size and has good flow performance. It is equipped with a reasonable volute, making the pump have an impeller After dynamic and static balance tests, the pump has no vibration during operation. Commonly used models are: GW50-20-7-0.75, GW25-8-22-1.1, GW50-10-10-0.75, GW50-20-15-1.5, GW50-15-25-2.2, GW50-18-30- 3. GW50-40-15-4, GW50-20-40-7.5, GW65-37-13-3, GW80-40-7-2.2, GW80-43-13-3, GW80-40-15-4, GW80-65-25-7.5, GW100-80-10-4, GW100-100-15-7.5, GW100-80-20-7.5, GW100-100-30-15, GW100-100-35-18.5, GW150- 145-9-7.5, GW150-180-15-15 and other series
GW pipeline non-clogging sewage pump model meaning
Model: 100GW100-15-7.5
100 represents the discharge diameter of the pump (mm)
GW stands for pipeline sewage pump
100 represents the pump flow rate 100 (L/S)
15 represents the Yang Cheng of the pump 15 (m)
7.5 represents the pump motor power of 7.5 (KW).
Features of GW pipeline non-blocking sewage pump
1. The pump and motor are directly connected coaxially. It is an electromechanical integration product with compact structure and stable performance.
2. The large flow channel anti-clogging hydraulic component design greatly improves the dirt passing capacity, and can effectively pass through 5 times the fiber material of the pump diameter and solid particles with a diameter of about 50% of the pump diameter.
3. Reasonable design, reasonable matching motor, high efficiency, low noise, and significant energy saving effect.
4. The mechanical seal is made of hard wear-resistant tungsten carbide, which is durable and wear-resistant, allowing the pump to operate safely and continuously for more than 8,000 hours.
5. The pump has a vertical structure, the center lines of the inlet and outlet are on the same horizontal line, and the inlet and outlet flanges have the same specifications, making installation and disassembly very convenient.
6. It occupies a small area and does not need to build a machine room, which can save a lot of infrastructure costs. With a protective cover on the blade end of the motor, the whole machine can be placed outdoors for operation.
Main uses of GW pipeline non-clogging sewage pump:
1. Sewage discharge from hospitals, hotels and high-rise buildings.
2. Discharge of thin mud from municipal projects and construction sites.
3. Wastewater discharge from breeding farms and rural farmland irrigation.
4. It is the water supply device of the water plant.
5. Mine exploration and water treatment equipment matching.
6. Water supply and drainage of water conservancy projects.
7. Wastewater discharge from enterprises and units.
8. Urban sewage treatment plant discharge system.
9. Sewage drainage stations in residential areas.
10. Subway, basement, civil air defense system drainage station.
Conditions for use of GW pipeline non-clogging sewage pump
1. The temperature of the transported medium does not exceed 80 degrees Celsius.
2. The weight of the transported medium is 1~1.3Kg/dm3.
3. The pump is mainly made of cast iron and cannot be used to transport highly corrosive liquids.
4. When the water pump is working, the area around the pump should be well ventilated.
5. 1Cr18Ni9Ti stainless steel material can be used to transport various corrosive liquids.
If users have special requirements, please indicate the relevant conditions of the conveying medium when ordering so that our company can provide more reliable products.
Installation and use of GW pipeline non-clogging sewage pump
1. First check whether the external fasteners have become loose during transportation.
2. Check whether the power supply voltage meets the requirements on the motor nameplate.
3. Turn on the power and make a test run to see if the impeller rotates in the direction indicated on the pump. If the direction is reversed, just swap any two-phase wires in the cable. The test run should not take too long to avoid burning the seal. .
4. Install the pump and start it up. Then install the pump foot screws.
GW pipeline non-clogging sewage pump inspection and maintenance
1. Before using the pump, check the insulation resistance of the motor winding to the casing. If it is lower than 0.5 megohm, the stator must be dried until the insulation resistance rises before use.
2. If the gap between the impeller and the oil seal at the inlet of the pump body exceeds 2mm, the wear-resistant oil seal should be replaced.
3. When the pump seal leaks, the seal should be replaced in time. When replacing, first install the static seal flat and solid, and then install the dynamic seal on the shaft.
4. When replacing the impeller, use a tensioner to pull it out and do not hit it with a hammer to avoid damaging the axis.
Common causes of failure of GW pipeline non-clogging sewage pump
1. No water comes out, the weight and particle size of the pumped liquid are too high; the liquid flow channel is blocked; the impeller turns in the wrong direction; the bar material is pumped into the impeller and is stuck; the pipe outlet height exceeds the rated lift height.
2. Insufficient flow and low head. The voltage is low, the impeller turns in the wrong direction or the wear-resistant seal is worn; the liquid is too heavy and granular.
3. The insulation resistance is low, the surrounding environment is humid, and the mechanical seal leaks seriously.
Performance parameters of non-clogging sewage pump in GW pipeline
GW pipeline non-clogging sewage pump model | Caliber | Flow | Lift | Speed | Motor Power | Efficiency |
mm | m3/h | M | r/min | kw | % | |
GW25-8-22-1.1 | 25 | 8 | 22 | 2900 | 1.1 | 45 |
GW32-12-15-1.1 | 32 | 12 | 15 | 2900 | 1.1 | 49 |
GW40-15-15-1.5 | 40 | 15 | 15 | 2900 | 1.5 | 54 |
GW40-15-30-2.2 | 40 | 15 | 30 | 2900 | 2.2 | 54 |
GW50-20-7-0.75 | 50 | 20 | 7 | 2900 | 0.75 | 51 |
GW50-10-10-0.75 | 50 | 10 | 10 | 2900 | 0.75 | 52 |
GW50-20-15-1.5 | 50 | 20 | 15 | 290 | 1.5 | 53 |
GW50-15-25-2.2 | 50 | 15 | 25 | 2900 | 2.2 | 54 |
GW50-18-30-3 | 50 | 18 | 30 | 2900 | 3 | 55 |
GW50-40-15-4 | 50 | 40 | 15 | 2900 | 4 | 55 |
GW50-25-32-5.5 | 50 | 25 | 32 | 2900 | 5.5 | 55 |
GW50-20-40-7.5 | 50 | 50 | 20 | 2900 | 7.5 | 58 |
GW65-25-15-2.2 | 65 | 25 | 15 | 2900 | 2.2 | 50 |
GW65-37-13-3 | 65 | 37 | 13 | 2900 | 3 | 57 |
GW65-25-30-4 | 65 | 25 | 30 | 2900 | 4 | 61 |
GW65-30-40-7.5 | 65 | 30 | 40 | 2900 | 7.5 | 56 |
GW65-35-50-11 | 65 | 35 | 50 | 2900 | 11 | 45 |
GW65-35-60-15 | 65 | 35 | 60 | 2900 | 15 | 65 |
GW80-60-13-5.5 | 80 | 60 | 13 | 2900 | 5.5 | 67 |
GW80-40-7-2.2 | 80 | 40 | 7 | 1450 | 2.2 | 59 |
GW80-43-13-3 | 80 | 43 | 13 | 2900 | 3 | 70 |
GW80-40-15-4 | 80 | 40 | 15 | 2900 | 4 | 61 |
GW80-65-25-7.5 | 80 | 65 | 25 | 2900 | 7.5 | 63 |
GW100-80-10-4 | 100 | 100 | 10 | 1450 | 4 | 65 |
GW100-110-10-5.5 | 100 | 110 | 10 | 1450 | 5.5 | 65 |
GW100-100-15-7.5 | 100 | 100 | 15 | 1450 | 7.5 | 68 |
GW100-80-20-7.5 | 100 | 80 | 20 | 1450 | 7.5 | 65 |
GW100-100-25-11 | 100 | 100 | 25 | 1450 | 11 | 70 |
GW100-100-30-15 | 100 | 100 | 30 | 1450 | 15 | 65 |
GW100-100-35-18.5 | 100 | 100 | 35 | 1450 | 18.5 | 68 |
GW125-130-15-11 | 125 | 130 | 15 | 1450 | 11 | 72 |
GW125-130-20-15 | 125 | 130 | 20 | 1450 | 15 | 75 |
GW150-145-9-7.5 | 150 | 145 | 9 | 1450 | 7.5 | 76 |
GW150-180-15-15 | 150 | 180 | 15 | 1450 | 15 | 69 |
GW150-180-20-18.5 | 150 | 180 | 20 | 1450 | 18.5 | 72 |
GW150-180-25-22 | 150 | 180 | 25 | 1450 | 22 | 78 |
GW150-130-30-22 | 150 | 130 | 30 | 1450 | 22 | 78 |
GW150-180-30-30 | 150 | 180 | 30 | 1450 | 30 | 78 |
GW150-200-30-37 | 150 | 200 | 30 | 1450 | 37 | 73 |
GW200-300-7-11 | 200 | 300 | 7 | 980 | 11 | 66 |
GW200-250-11-15 | 200 | 250 | 11 | 1450 | 15 | 64 |
GW200-250-15-18.5 | 200 | 250 | 15 | 1450 | 18.5 | 73 |
GW200-400-10-22 | 200 | 400 | 10 | 1450 | 22 | 75 |
GW200-400-13-30 | 200 | 400 | 13 | 1450 | 30 | 76 |
GW200-300-15-22 | 200 | 300 | 15 | 1450 | 22 | 76 |
GW200-250-22-30 | 200 | 250 | 22 | 1450 | 30 | 71 |
GW200-350-25-37 | 200 | 350 | 25 | 1450 | 37 | 71 |
GW200-400-30-45 | 200 | 400 | 30 | 1450 | 45 | 74 |
GW250-600-9-30 | 250 | 600 | 9 | 980 | 30 | 78 |
GW250-600-12-37 | 250 | 600 | 12 | 1450 | 37 | 76 |
GW250-600-15-45 | 250 | 600 | 15 | 1450 | 45 | 73 |
GW250-600-20-55 | 250 | 600 | 20 | 1450 | 55 | 73 |
GW250-600-25-75 | 250 | 600 | 25 | 1450 | 75 | 71 |
GW300-800-12-45 | 300 | 800 | 12 | 980 | 45 | 74 |
GW300-480-15-45 | 300 | 480 | 15 | 1450 | 45 | 66 |
GW300-800-15-55 | 300 | 800 | 15 | 1450 | 55 | 73 |
GW300-600-20-55 | 300 | 600 | 20 | 1450 | 55 | 73 |
GW300-800-20-75 | 300 | 800 | 20 | 1450 | 75 | 75 |
GW300-950-20-90 | 300 | 950 | 20 | 1450 | 90 | 76 |
GW300-1000-25-110 | 300 | 1000 | 25 | 1450 | 110 | 76 |
GW300-1100-10-55 | 300 | 1100 | 10 | 1450 | 55 | 73 |
GW350-1500-15-90 | 350 | 1500 | 15 | 740 | 90 | 87 |
GW350-1200-18-90 | 350 | 1200 | 18 | 980 | 90 | 85 |
GW350-1100-28-132 | 350 | 1100 | 28 | 980 | 132 | 84 |
GW350-1000-36-160 | 350 | 1000 | 36 | 980 | 160 | 84 |
GW400-1760-7.5-55 | 400 | 1760 | 7.5 | 980 | 55 | 83 |
GW400-1500-10-75 | 400 | 1500 | 10 | 980 | 75 | 86 |
GW400-2000-13-110 | 400 | 2000 | 13 | 980 | 110 | 84 |
GW400-2000-15-132 | 400 | 2000 | 15 | 980 | 132 | 83 |
GW400-1700-22-160 | 400 | 1700 | 22 | 980 | 160 | 83 |
GW400-1500-26-160 | 400 | 1500 | 26 | 980 | 160 | 84 |
GW400-1700-30-200 | 400 | 1700 | 30 | 980 | 200 | 86 |
GW400-1800-32-250 | 400 | 1800 | 32 | 980 | 250 | 82 |
GW500-2500-10-110 | 500 | 2500 | 10 | 740 | 110 | 85 |
GW500-2600-15-160 | 500 | 2600 | 15 | 740 | 160 | 84 |
GW500-2400-22-220 | 500 | 2400 | 22 | 740 | 220 | 85 |
GW500-2650-24-250 | 500 | 2650 | 24 | 740 | 250 | 85 |
Export wooden box packaging
Principles for selecting sewage pumps - DFIN Pump Industry
1. High mechanical reliability, low noise, and minimal vibration.
2. Economically, it is necessary to comprehensively consider the total cost of equipment, operation, maintenance, and management fees to minimize them.
3. Make the selected pump type and performance meet the requirements of process parameters such as device flow rate, head, pressure, temperature, cavitation flow rate, and suction stroke.
4. Must meet the requirements of medium characteristics.
For pumps that transport flammable, explosive, toxic, or valuable media, reliable shaft seals or leak free pumps are required, such as magnetic drive pumps, diaphragm pumps, and shielded pumps
For pumps transporting corrosive media, it is required that the convection components use corrosion-resistant materials, such as AFB stainless steel corrosion-resistant pumps and CQF engineering plastic magnetic drive pumps.
For pumps transporting media containing solid particles, it is required that the convection components be made of wear-resistant materials, and if necessary, the shaft seal should be flushed with clean liquid.