Customization: | Available |
---|---|
After-sales Service: | One Year |
Warranty: | One Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
80GNWQ60-16-5.5 Clog-free vertical cutting sewage submersible pump It is widely used in communities, municipal pipe networks, comprehensive sewage treatment plants, sewage treatment equipment in building basements, subway projects, etc. It is especially suitable for wastewater containing long fibers in the medium. Wastewater discharge from food, leather, pulp, printing and dyeing, steel and other products. Sewage discharge from slaughterhouses and rural biogas pools. Industrial drainage, other water use, and drainage for other purposes.
The electric pump of the submersible sewage pump with cutting knife uses high-quality carbide, a dynamic sealing structure that combines double-end mechanical seals and skeleton oil seals. For the normal operation of the electric pump and the safety of workers, users should equip the electric motor with a leakage protector. , when working for a long time, the motor of this pump is allowed to expose the liquid surface, which shall not exceed 1/2 of the height of the motor, and the temperature of the pumped dirt shall not exceed 40°C. The submersible sewage pump with cutting knife has a particularly strong sewage passing capacity and good belt cutting performance. It can chop long fibers, plastics, paper, belts, cloth strips, straw, rope and other impurities in the sewage and discharge them.
GNWQ sewage cutting sewage pump Model meaning
80GNWQ60-16-5.5 Clog-free vertical cutting sewage submersible pump is a cutting type sewage sewage pump, which is designed to transport sewage and dirt. Its cutting part has a unique spiral structure and a sharp blade design. The material is made of material with a Rockwell hardness of 48HR or above (special materials need to be customized in advance) . On the premise of ensuring high water conservancy performance and exceeding similar products, it also has a certain cutting ability to ensure the superior cutting function of straw, cotton, cloth, baby diapers and other wastes after being chopped and discharged. GNWQ series sewage cutting pump is suitable for 0-25 meters, large flow, medium and low lift, full lift and low energy consumption. This product also adopts a removable cutterhead design. Different types of cutterheads can be replaced according to different usage environments, including municipal type and special type for livestock farms.
80GNWQ60-16-5.5 Clog-free vertical cutting sewage submersible pump working conditions:
1. The medium temperature does not exceed 60ºC, the maximum medium temperature in continuous use does not exceed 50ºC, the medium density is 1.0-1.3×1000kg/m3, and the PH value is in the range of 5-9;
2. When the water pump is working, the motor part should not be exposed more than 1/2 of the water;
3. The main parts of this type of pump are made of cast iron, so it cannot be used to pump highly corrosive liquids;
Note: If users have special requirements, they can put them forward when ordering in order to provide more reliable products.
The submersible reamer pump adopts the design of large-channel anti-clogging hydraulic components and can effectively pass solid particles with a diameter of 50-125mm. The water pump components are well designed, and a cutting rotary cutter head is installed in front of the impeller so that impurities in the pumped medium are crushed before entering the impeller flow channel without clogging.The automatic coupling system is easy to install and does not need to build a pump room, which can reduce a lot of engineering costs and operating costs.
Precautions for use of submersible sewage pump with cutting knife
(1) Before using the electric pump, you must first check whether the cable is damaged. When transporting and installing the water pump, cut the iron to pull or damage the cable to avoid accidents caused by water leakage after the cable ruptures. If the cable is hard to crack, the cable should be replaced immediately. And use a megohmmeter to check whether the insulation resistance of the electric pump is normal (the insulation resistance must not be less than 1 megohm)
(2) Recognize the grounding wire (the grounding wire is usually yellow or green or connected with a grounding mark), and connect the grounding wire according to the prescribed procedures. (Our factory's ground wire is equipped with a ground mark).
(3) Choose a suitable protector (such as leakage protector, air switch, phase failure overcurrent protector, etc.) and do not connect directly with a knife switch.
(4) Connect the power cord according to the standard, test the power supply, check whether the electric pump is operating normally, and determine whether the steering is correct. If the steering is incorrect, just swap any two of the three power cords (pay attention to the operation) The time cannot exceed half a minute).
(5) Install the water outlet joint and water outlet hose (or iron pipe), tie a rope on the handle of the electric pump (cables must not be used to replace the hanging rope), put the electric pump into the liquid book to be pumped, and turn on the power supply and is ready to use.
(6) In order to ensure personal safety, when the electric pump is connected to power, it is strictly prohibited to install and launch water operations near the electric pump (such as moving or inspecting, troubleshooting, etc.) and touching the electric pump to prevent accidents caused by electric pump leakage!
(7) It is strictly prohibited for the entire electric pump to be exposed to the water for long-term operation (or short-term operation). The "start" and "stop" of the electric pump should not be too frequent to prevent overheating and damage to the motor.
(8) Long-term pumping of liquids with high sand content will cause greater wear and tear on the flow-passing parts of the GNWQ sewage pump with cutting device. It is recommended to use our cyclonic sewage submersible electric pump product.
(9) If it is found that the GNWQ sewage pump with cutting device does not rotate, the protector trips, the fuse blows, etc. when it is running, the power supply should be cut off immediately and check whether there are any problems with the power protector wiring, etc.
If these external devices are normal, the electric pump may be faulty and should not be used at this time to avoid an accident!
GNWQ double reamer cutting sewage pump Model meaning
GNWQ Model | Flow | Lift | Power | Voltage | Caliber |
(m³/h) | (m) | (kW) | (V) | (mm) | |
50GNWQ10-10-0.75 | 10 | 10 | 0.75 | 220/380 | 50 |
50GNWQ12-10-1.1 | 12 | 10 | 1.1 | 220/380 | 50 |
50GNWQ15-15-1.5 | 15 | 15 | 1.5 | 220 | 50 |
50GNWQ15-15-1.5 | 15 | 15 | 1.5 | 380 | 50 |
65GNWQ20-10-1.5 | 20 | 10 | 1.5 | 220 | 65 |
65GNWQ20-10-1.5 | 20 | 10 | 1.5 | 380 | 65 |
50GNWQ20-15-2.2 | 20 | 15 | 2.2 | 380 | 50 |
65GNWQ25-15-2.2 | 25 | 15 | 2.2 | 380 | 65 |
80GNWQ35-12-2.2 | 35 | 12 | 2.2 | 380 | 80 |
50GNWQ25-16-3 | 25 | 16 | 3 | 380 | 50 |
50GNWQ15-20-3 | 15 | 20 | 3 | 380 | 50 |
65GNWQ35-16-3 | 35 | 16 | 3 | 380 | 65 |
80GNWQ35-15-3 | 30 | 16 | 3 | 380 | 80 |
50GNWQ25-22-4 | 25 | 22 | 4 | 380 | 50 |
65GNWQ35-18-4 | 35 | 18 | 4 | 380 | 65 |
80GNWQ50-18-4 | 50 | 18 | 4 | 380 | 80 |
100GNWQ60-12-4 | 60 | 12 | 4 | 380 | 100 |
65GNWQ40-20-5.5 | 40 | 20 | 5.5 | 380 | 65 |
80GNWQ60-16-5.5 | 60 | 16 | 5.5 | 380 | 80 |
100GNWQ70-15-5.5 | 70 | 15 | 5.5 | 380 | 100 |
65GNWQ40-25-7.5 | 40 | 25 | 7.5 | 380 | 65 |
80GNWQ80-20-7.5 | 80 | 20 | 7.5 | 380 | 80 |
100GNWQ100-15-7.5 | 100 | 15 | 7.5 | 380 | 100 |
150GNWQ120-10-7.5 | 120 | 10 | 7.5 | 380 | 150 |
100GNWQ120-18-11 | 120 | 18 | 11 | 380 | 100 |
150GNWQ150-15-11 | 150 | 15 | 11 | 380 | 150 |
100GNWQ150-18-15 | 150 | 18 | 15 | 380 | 100 |
150GNWQ200-15-15 | 200 | 15 | 15 | 380 | 150 |
150GNWQ180-20-18.5 | 180 | 20 | 18.5 | 380 | 150 |
200GNWQ250-15-18.5 | 250 | 15 | 18.5 | 380 | 200 |
150GNWQ200-20-22 | 250 | 15 | 22 | 380 | 150 |
200GNWQ300-15-22 | 300 | 15 | 22 | 380 | 200 |
Scope of application of submersible sewage pump with cutting knife
Submersible sewage pumps with cutting blades are mainly used for engineering sewage and domestic sewage.
like:
(1) Sewage treatment and circulating water transportation for small and medium-sized enterprises.
(2) Slag slurry pumping in factories and mines such as food, papermaking, brewing, steel and non-ferrous metals, tanning, textiles, pharmaceuticals, cement plants, etc.
(3) Used in construction sites, engineering foundation construction, municipal facilities, and water plants.
(4) Sewage discharge from underground basements of various high-rise buildings, civil air defense pits, subways, etc.
(5) Chicken farms, pig farms, various breeding industries, fish ponds are used for pumping water to clear ponds, increasing oxygenation, pumping human and animal excrement and urine in septic tanks and other occasions.
Note: The main performance and data of the submersible sewage pump with cutting knife are the same as the wqk/qg type except that it does not have a cutting device.
Conditions for use of submersible sewage pump with cutting knife:
1. The medium temperature does not exceed 40ºC.
2. The average weight of the medium does not exceed 500 kilograms per cubic meter.
3. The pH value of the pumped liquid is 5 to 9.
4. During long-term operation, the part of the motor allowed to be exposed to the liquid surface shall not exceed l/2 of the height.
Export wooden box packaging
Principles for selecting sewage pumps - DFIN Pump Industry
1. High mechanical reliability, low noise, and minimal vibration.
2. Economically, it is necessary to comprehensively consider the total cost of equipment, operation, maintenance, and management fees to minimize them.
3. Make the selected pump type and performance meet the requirements of process parameters such as device flow rate, head, pressure, temperature, cavitation flow rate, and suction stroke.
4. Must meet the requirements of medium characteristics.
For pumps that transport flammable, explosive, toxic, or valuable media, reliable shaft seals or leak free pumps are required, such as magnetic drive pumps, diaphragm pumps, and shielded pumps
For pumps transporting corrosive media, it is required that the convection components use corrosion-resistant materials, such as AFB stainless steel corrosion-resistant pumps and CQF engineering plastic magnetic drive pumps.
For pumps transporting media containing solid particles, it is required that the convection components be made of wear-resistant materials, and if necessary, the shaft seal should be flushed with clean liquid.