65wqd25-10-1.8 Anti-Tangle Non-Clogging Septic Tank Agricultural Alloy Double Knife Cutting Pump

Product Details
Customization: Available
After-sales Service: One Year
Warranty: One Year
Diamond Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
Self-branded
The supplier has 1 Self-brands, check the Audit Report for more information
In-stock Capacity
The supplier has In-stock capacity
to see all verified strength labels (13)
  • 65wqd25-10-1.8 Anti-Tangle Non-Clogging Septic Tank Agricultural Alloy Double Knife Cutting Pump
  • 65wqd25-10-1.8 Anti-Tangle Non-Clogging Septic Tank Agricultural Alloy Double Knife Cutting Pump
  • 65wqd25-10-1.8 Anti-Tangle Non-Clogging Septic Tank Agricultural Alloy Double Knife Cutting Pump
  • 65wqd25-10-1.8 Anti-Tangle Non-Clogging Septic Tank Agricultural Alloy Double Knife Cutting Pump
  • 65wqd25-10-1.8 Anti-Tangle Non-Clogging Septic Tank Agricultural Alloy Double Knife Cutting Pump
  • 65wqd25-10-1.8 Anti-Tangle Non-Clogging Septic Tank Agricultural Alloy Double Knife Cutting Pump
Find Similar Products

Basic Info.

Model NO.
65WQD25-10-1.8
Max.Capacity
>400 L/min
Driving Type
Motor
Material
Stainless Steel
Structure
Single-stage Pump
Assembly
Liquid Pumps
Power
Electric
Start Up
Electric Pump
Type
Blade Pump
Application
Submersible Pump, Clarified Water Pump, Sewage Pump
Industry
Clear Water Pump
Media
Sewage Pumps
Performance
Wear Pump
Theory
Centrifugal Pump
Transport Package
Wooden Box
Specification
Stainless steel
Trademark
DfinPump
Origin
Shanghai
Production Capacity
10000

Product Description

65WQD25-10-1.8 Anti-tangle non-clogging septic tank agricultural alloy double knife cutting pump

cutting-type submersible sewage pump adopts double-end mechanical seal and rotating impeller. The impeller is made of stainless steel, which is wear-resistant, non-clogging and non-winding. It has the advantages of small size, compact structure and easy portability. cutting submersible sewage pump is mainly used to discharge domestic wastewater, sewage, human feces and solid suspended solids and non-corrosive media containing short fiber paper chips, wood chips, starch, sediment, ore particles, etc. The temperature of the pumped liquid does not vary. Over 40ºC, density not more than 1200kg/m3, ph value 6~9

65wqd25-10-1.8 Anti-Tangle Non-Clogging Septic Tank Agricultural Alloy Double Knife Cutting Pump

65WQD25-10-1.8 Anti-tangle non-clogging septic tank agricultural alloy double knife cutting pump

 

The electric pump of the submersible sewage pump with cutting knife uses high-quality carbide, a dynamic sealing structure that combines double-end mechanical seals and skeleton oil seals. For the normal operation of the electric pump and the safety of workers, users should equip the electric motor with a leakage protector. , when working for a long time, the motor of this pump is allowed to expose the liquid surface, which shall not exceed 1/2 of the height of the motor, and the temperature of the pumped dirt shall not exceed 40°C.

 

 Cutting  lift septic tank biogas debris mud submersible sewage pump

The cutting pump is a pump specially used for cutting solid objects. It is mainly used to handle liquids containing solid materials such as fibers, cloth, waste, and suspended solids. Cutting pumps are usually used in sewage treatment, industrial sewage, papermaking, textiles, food processing and other fields to handle liquids that need to cut solid objects.

 

65wqd25-10-1.8 Anti-Tangle Non-Clogging Septic Tank Agricultural Alloy Double Knife Cutting Pump

 

65WQD25-10-1.8 Anti-tangle non-clogging septic tank agricultural alloy double knife cutting pump

It has strong sewage passing capacity and good belt cutting performance. It can chop long fibers, plastics, paper, belts, cloth strips, straw, rope and other impurities in the sewage and discharge them. WQK sewage pump with cutting device is especially suitable for narrow working surfaces such as shipbuilding, communications, shipping, basements, and excavation of ponds and rivers, especially individual food processing plants, individual breeding sites, drilling industries, water pit wells, and paper mills , used in paint factories. 

 

 

Scope of application of  cutting submersible sewage pump

65wqd25-10-1.8 Anti-Tangle Non-Clogging Septic Tank Agricultural Alloy Double Knife Cutting Pump

 cutting submersible sewage pump is mainly used for engineering sewage and domestic sewage.

like: 

(1) Sewage treatment and circulating water transportation for small and medium-sized enterprises.

(2) Slag slurry pumping in factories and mines such as food, papermaking, brewing, steel and non-ferrous metals, tanning, textiles, pharmaceuticals, cement plants, etc.

(3) Used in construction sites, engineering foundation construction, municipal facilities, and water plants.

(4) Sewage discharge from underground basements of various high-rise buildings, civil air defense pits, subways, etc.

(5) Chicken farms, pig farms, various breeding industries, fish ponds are used for pumping water to clear ponds, increasing oxygenation, pumping human and animal excrement and urine in septic tanks and other occasions.

Note: The main performance and data of the   cutting submersible sewage pump are the same as those of the wqk/qg type except that it does not have a cutting device.

 

65WQD25-10-1.8 Anti-tangle non-clogging septic tank agricultural alloy double knife cutting pump

Conditions for use of  cutting submersible sewage pump:

 

1. The medium temperature does not exceed 40ºC.

2. The average weight of the medium does not exceed 500 kilograms per cubic meter.

3. The pH value of the liquid being pumped is 5 to 9.

4. During long-term operation, the part of the motor allowed to be exposed to the liquid surface shall not exceed l/2 of the height.

 

65WQD25-10-1.8 Anti-tangle non-clogging septic tank agricultural alloy double knife cutting pump

 

Precautions for use of  cutting submersible sewage pump

65wqd25-10-1.8 Anti-Tangle Non-Clogging Septic Tank Agricultural Alloy Double Knife Cutting Pump

(1) Before using the electric pump, you must first check whether the cable is damaged. When transporting and installing the water pump, cut the iron to pull or damage the cable to avoid accidents caused by water leakage after the cable ruptures. If the cable is hard to crack, the cable should be replaced immediately. And use a megohmmeter to check whether the insulation resistance of the electric pump is normal (the insulation resistance must not be less than 1 megohm)

(2) Recognize the grounding wire (the grounding wire is usually yellow or green or connected with a grounding mark), and connect the grounding wire according to the prescribed procedures. (Our factory's ground wire is equipped with a ground mark).

(3) Choose a suitable protector (such as leakage protector, air switch, phase failure overcurrent protector, etc.) and do not connect directly with a knife switch.

(4) Connect the power cord according to the standard, test the power supply, check whether the electric pump is operating normally, and determine whether the steering is correct. If the steering is incorrect, just swap any two of the three power cords (pay attention to the operation) The time cannot exceed half a minute).

(5) Install the water outlet joint and water outlet hose (or iron pipe), tie a rope on the handle of the electric pump (cables must not be used to replace the hanging rope), put the electric pump into the liquid book to be pumped, and turn on the power supply and is ready to use.

(6) In order to ensure personal safety, when the electric pump is connected to power, it is strictly prohibited to install and launch water operations near the electric pump (such as moving or inspecting, troubleshooting, etc.) and touching the electric pump to prevent accidents caused by electric pump leakage!

(7) It is strictly prohibited for the entire electric pump to be exposed to the water for long-term operation (or short-term operation). The "start" and "stop" of the electric pump should not be too frequent to prevent overheating and damage to the motor.

(8) Long-term pumping of liquids with high sand content will cause greater wear and tear on the flow-passing parts of the   sewage pump with cutting device. It is recommended to use our cyclonic sewage submersible electric pump product.

(9) If it is found that the   sewage pump with cutting device does not rotate, the protector trips, the fuse blows out and other abnormal phenomena when it is running, the power should be cut off immediately and check whether there are any problems with the power protector wiring, etc.

If these external devices are normal, the electric pump may be faulty and should not be used at this time to avoid an accident!

 


65wqd25-10-1.8 Anti-Tangle Non-Clogging Septic Tank Agricultural Alloy Double Knife Cutting Pump

 

 304 material alloy steel double reamer crushing sewage pump

cutting submersible sewage pump maintenance

 

1. After each use, especially for thicker and more viscous slurries, it should be placed in clean water for a few minutes before storage.

2. After every 300 to 500 hours of use of the electric pump, the waist oil hole screw should be opened and replenished with pure No. 10 engine oil, and a mechanical seal should be used to maintain good lubrication. If a large amount of water is found in the oil chamber, it indicates that the mechanical seal has failed and should be replaced.

3. The electric pump should be managed and used by dedicated personnel, and the insulation resistance between the electric pump winding and the casing should be regularly checked to see if it is normal and must not be less than 0.5 megohms. Otherwise, the stator must be removed and dried, and the insulation resistance can be used only after the insulation resistance rises.

4. After the electric pump is started, if it is found that the flow rate is insufficient or the lift is lower than the specified value (unless the pipeline resistance is large or blocked), the direction may be reversed. At this time, the power supply should be disconnected and any two of the three phase wires of the cable should be swapped with each other. Finally, connect the new meter and start again.

5. After the electric pump is disassembled and repaired, the sealing performance must be checked by a 0.2MPa air tightness test.

6. If the elbow and electric pump are placed separately in the crate, please install the elbow on the electric pump. If the electric pump is connected to the pipeline, there is no need to install the elbow.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier
Product Categories